# Copyright(c) 1986 Association of Universities for Research in Astronomy Inc. include include include include "imd.h" # IMD_OPENWS -- Open the named workstation. Once a workstation has been # opened we leave it open until some other workstation is opened or the # kernel is closed. Opening a workstation involves initialization of the # kernel data structures, following by initialization of the device itself. procedure imd_openws (devname, n, mode) short devname[ARB] # device name int n # length of device name int mode # access mode pointer sp, buf pointer ttygdes() bool streq() int idk_open() bool need_open, same_dev include "imd.com" begin call smark (sp) call salloc (buf, max (SZ_FNAME, n), TY_CHAR) # If a device was named when the kernel was opened then output will # always go to that device (g_device) regardless of the device named # in the OPENWS instruction. If no device was named (null string) # then unpack the device name, passed as a short integer array. if (g_device[1] == EOS) { call achtsc (devname, Memc[buf], n) Memc[buf+n] = EOS } else call strcpy (g_device, Memc[buf], SZ_FNAME) # Find out if first time, and if not, if same device as before # note that if (g_kt == NULL), then same_dev is false. same_dev = false need_open = true if (g_kt != NULL) { same_dev = (streq (Memc[IMD_DEVNAME(g_kt)], Memc[buf])) if (!same_dev) { # Does this device require a frame advance at end of metafile? if (IMD_ENDFRAME(g_kt) == YES) call idk_frame (g_out) call idk_close (g_out) } else need_open = false } # Initialize the kernel data structures. Open graphcap descriptor # for the named device, allocate and initialize descriptor and common. # graphcap entry for device must exist. if (need_open) { if (!same_dev) { if (g_kt != NULL) call ttycdes (g_tty) iferr (g_tty = ttygdes (Memc[buf])) call erract (EA_ERROR) # Initialize data structures if we had to open a new device. call imd_init (g_tty, Memc[buf]) call imd_reset() } # Open the output file. Metacode output to the device will be # spooled and then disposed of to the device at CLOSEWS time. iferr (g_out = idk_open (g_frame, g_color, g_tty)) { call ttycdes (g_tty) call erract (EA_ERROR) } else { # Does this device require a frame advance at start of metafile? if (IMD_STARTFRAME(g_kt) == YES) call idk_frame (g_out) g_nframes = 0 g_ndraw = 0 } } # Clear the screen if device is being opened in new_file mode. # This is a nop if we really opened a new device, but it will clear # the screen if this is just a reopen of the same device in new file # mode. if (mode == NEW_FILE) call imd_clear (0) call sfree (sp) end