diff options
author | Joe Hunkeler <jhunkeler@gmail.com> | 2015-08-11 16:51:37 -0400 |
---|---|---|
committer | Joe Hunkeler <jhunkeler@gmail.com> | 2015-08-11 16:51:37 -0400 |
commit | 40e5a5811c6ffce9b0974e93cdd927cbcf60c157 (patch) | |
tree | 4464880c571602d54f6ae114729bf62a89518057 /pkg/xtools/icfit/Revisions | |
download | iraf-osx-40e5a5811c6ffce9b0974e93cdd927cbcf60c157.tar.gz |
Repatch (from linux) of OSX IRAF
Diffstat (limited to 'pkg/xtools/icfit/Revisions')
-rw-r--r-- | pkg/xtools/icfit/Revisions | 405 |
1 files changed, 405 insertions, 0 deletions
diff --git a/pkg/xtools/icfit/Revisions b/pkg/xtools/icfit/Revisions new file mode 100644 index 00000000..0117042e --- /dev/null +++ b/pkg/xtools/icfit/Revisions @@ -0,0 +1,405 @@ +.help revisions Jun88 pkg.xtools.icfit +.nf +icdeviant.gx + There were two bugs related to growing. First, the logic was wrong. + Second, in one place the grow parameter was treated as being in pixels + and in another as being in user coordinate units. + (6/28/10, Valdes) + +icdosetup.gx + When there is only one sample range that is binned to a single point + this would result in the fitting limits (introduced 8/11/00) being + equal. This causes cvinit to return an error and the cv pointer + is invald. The change is if the number of binned fitting points + is 1 then the full range of the unbinned data is used. Note that + a change was also made on this date to have cvinit return a null + pointer rather than a partially initialized pointer. (11/18/02, Valdes) + +======= +V2.12.1 +======= + +===== +V2.12 +===== + +icdosetup.gx + The change made previously is now restricted to the polynomial functions + which make sense to extrapolate. The spline functions define the + fitting region to be the region set by the calling program. + (11/21/00, Valdes) + +icfshow.gx + Will now work if the GT pointer is NULL. (8/19/00, Valdes) + +icdosetup.gx + When using sample ranges the fitting region is now limited to the + minimum and maximum of the fitted region. (8/11/00, Valdes) + +========= +V2.11.3p1 +========= +======= +V2.11.3 +======= + +icgui.x + Eliminated gmsg calls when there is no GUI. (2/1/99, Valdes) + +icshow.x +icvshow.gx + The gt pointer was not being used when called by CURFIT noninteractively. + The IC_GT structure is now set in these routines. (9/14/99, Valdes) + +======= +V2.11.2 +======= + +icggraph.gx + Moved smark to after an initial return. (7/11/99, Valdes) + +icgfit.x + This routine is called with a graphics descriptor for interactive + fitting. The descriptor is set in an internal structure. Other + procedures, which may be called both for interactive and + non-interactive fitting, check if the descriptor is not NULL + before sending GUI messages. The problem occurs if this procedure is + first called interactively and then the non-interactive fitting + routine is called later (maybe after a deactivate workstation or + closing the descriptor) resulting in GUI messages being sent + when not in interactive mode. The solution is to return the + internal descriptor value to NULL after finishing the interactive + fitting and returning from this procedure. (7/22/99, Valdes) + +icgui.x + Fixed bug in behavior when there is no gui. (4/2/99, Valdes) + +icfit.h +names.h +icgfit.gx +icparams.x +icggraph.gx +icgcolon.gx +icgui.x +icferrors.gx +icshow.x +icerrors.gx +icvshow.gx +icguishow.gx +icfvshow.gx +mkpkg + Added support for GUIs. (12/7/98, Valdes) + +======= +V2.11.1 +======= + +======= +V2.11.0 +======= + +pkg$xtools/icfit/icfit.hlp + Changed the order of the task name and version number in the revisions + section. (4/22/97, Valdes) + +pkg$xtools/icgcolon.gx +pkg$xtools/icfit/icfit.hlp + Changed the "fitvalue" colon command to "evaluate" to avoid abbreviation + conflict with "function". (4/16/97, Valdes) + +pkg$xtools/icfit/icshow.x + The commenting of the title string needed to be modified since the + title string could include new lines and we want each line to be + commented. (3/27/97, Valdes) + +pkg$xtools/icfit/icgcolon.gx +pkg$xtools/icfit/icfit.hlp + Added a "fitvalue" colon command to evaluate the fit at an arbitrary value. + (1/28/97, Valdes) + +pkg$xtools/icfit/icvshow.gx +pkg$xtools/icfit/icshow.x +pkg$xtools/icfit/icerrors.gx + All output except the tabular part of :xyshow now begins with + the comment character. Comment column labels were added back. + (2/29/96, Valdes) + +pkg$xtools/icfit/icvshow.gx +pkg$xtools/icfit/icgcolon.gx +pkg$xtools/icfit/icfit.help + Enhanced the :xyshow command to include the weights and not print + column labels. (11/20/95, Valdes) + +pkg$xtools/icfit/icparams.x + Added an ic_geti paramter "nmin" to return the minimum number of + points that can be fit. (9/8/95, Valdes) + +pkg$xtools/icfit/icgfit.h + The prototype capability of adding points was supposed to return to + the calling program as if only the original data was used however + the structure element giving the number of points fit was the number + after adding the points. This causes other routines to think the + data was sampled in some way which then leads to attempting to + reference a NULL array. The routine now sets the number of points + fit back to the input value upon completion. (7/12/95, Valdes) + +pkg$xtools/icfit/icfit.h +pkg$xtools/icfit/icparams.x +pkg$xtools/icfit/icggraph.gx +pkg$xtools/icfit/icgcolon.gx +pkg$xtools/icfit/icfit.hlp + Added a color option for the fit. Users may set it with :color and + applications with ic_puti. (6/30/95, Valdes) + +======= +V2.10.4 +======= + +pkg$xtools/icfit/icdosetup.gx + Fixed two type mismatches in min/max calls. (12/30/94, Valdes) + +pkg$xtools/icfit/icgfit.gx +pkg$xtools/icfit/icfit.hlp + Added 'v' key to change fitting weight. (12/29/94, Valdes) + +pkg$xtools/icparams.gx + Make it legal to call ic_closed with a null pointer. (8/11/93, Valdes) + +============ +V2.10.3 beta +============ + +pkg$xtools/icfit.gx + This procedure now sets the IC_FITERROR structure element so that + a program using only the noninteractive ic_fit will have this element + defined. The procedure will still return with an error condition + if an error occurs as was true previously. (6/29/93, Valdes) + +pkg$xtools/icdosetup.gx + The fitting min and max given to cvinit is now calculated from the data + avoiding errors in setting it by calling programs. This was especially + dangerous because fitting data outside this range can cause memory + corruption errors by the CURFIT routines. (7/29/92, Valdes) + +======= +V2.10.1 +======= + +pkg$xtools/icfit/icgcolon.gx +pkg$xtools/icfit/icggraph.gx +pkg$xtools/icfit/icparams.x +pkg$xtools/icfit/icfit.h +pkg$xtools/icfit/icfit.hlp +noao$lib/src/icgfit.key +noao$lib/src/idicgfit.key + Added a new user parameter called "markrej" to toggle whether to mark + rejected points or not. (1/21/92, Valdes) + +pkg$xtools/icfit/icfit.hlp +pkg$xtools/icfit/icgsample.gx +pkg$xtools/icfit/icgfit.gx +pkg$xtools/icfit/icgcolon.gx +pkg$xtools/icfit/icparams.x +pkg$xtools/icfit/icfit.h +pkg$xtools/icfit/icfit.hlp + 1. Added 'z' key to delete individual sample regions. + 2. Increased the internal sample string to 1024 characters. + (9/4/91, Valdes) + +pkg$xtools/icfit/icfit.hlp +pkg$xtools/icfit/icgfit.gx +pkg$xtools/icfit/icgadd.gx +pkg$xtools/icfit/ mkpkg + Added 'a' key to allow adding points for constraining the fit. + (9/3/91, Valdes) + +pkg$xtools/icfit/icfit.hlp + Fixed typo for :errors description. (11/20/90, Valdes) + +pkg$xtools/icfit/icgcolon.gx + 1. Unrecognized or ambiguous colon commands are now noted. + (10/2/90, Valdes) + +pkg$xtools/icfit/icvshow.gx +pkg$xtools/icfit/icgcolon.gx +pkg$xtools/icfit/icfit.hlp +noaolib$scr/icgfit.key + 1. The :vshow command now does not print the (x, y fit, y) values. + 2. A new user command, :xyshow, prints the (x, y fit, y) values. + (5/16/90, Valdes) + +==== +V2.9 +==== + +pkg$xtools/icfit/icparams.x +pkg$xtools/icfit/icgcolon.x + 1. ic_puti uses max (1, order) for setting the order. + 2. icg_colon prints error if attempting to set order < 1. + (3/6/90, Valdes) + +pkg$xtools/icfit/icparams.x + Added ability to get information about the number of fit points and the + rejected points to the ic_geti procedure. (5/4/89, Valdes) + +pkg$xtools/icfit/icggraph.gx + Scaled the symbol used for marking average points to the appropriate + coordinate system. This is still only approximately correct. + Based on a report by Ivo Busko. (3/1/89, Valdes) + +pkg$xtools/icfit/icvshow.gx + + Changed output format of 3 values so 7 digits of precision are printed. + This was in response to a user request for the utilities.curfit task, + but all programs calling icvshow will be affected. (ShJ 3-NOV-88) + +< call fprintf (fd, "RMS = %10.7g\n") +> call fprintf (fd, "RMS = %7.4g\n") + +< call fprintf (fd, "square root of reduced chi square = %10.7g\n") +> call fprintf (fd, "square root of reduced chi square = %7.4g\n") + +< call fprintf (fd, "\t%14.7e\t%14.7e\n") +> call fprintf (fd, "\t%10.4e\t%10.4e\n") + +pkg$xtools/icfit/icgfit.gx +pkg$xtools/icfit/icgaddfit.gx +noao$lib/scr/icgfit.key + Added 'I' interrupt key. (4/20/88 Valdes) + +pkg$xtools/icfit/icgfit.gx +pkg$xtools/icfit/icgparams.gx + Valdes, Jan. 5, 1988 + Added checks for an error in fitting the curve. + +pkg$xtools/icfit/icgfit.gx + Valdes, Oct. 2, 1987 + 1. When doing sample regions there was a round off problem with + negative numbers. Replaced int(x+.5) with nint(x). + +pkg$xtools/icfit/icfit.h +pkg$xtools/icfit/icparams.x +pkg$xtools/icfit/icguaxes.gx + Valdes, February 20,1987 + 1. Made the cursor help file a setable parameter since the graph + keys are definable by the application. + 2. Added the radial velocity axis type explicitly to the package + to remove the need for onedspec.identify to have it's own copy + of the package. + +pkg$xtools/icfit/*x + Valdes, February 17, 1987 + 1. Required GIO changes. + +pkg$xtools/icfit/icgcolon.gx + Valdes, January 16, 1987 + 1. Colon command dictionary and switch modified to use macro definitions. + +pkg$xtools/icfit/icgfit.gx +noao$lib/scr/icgfit.key +noao$lib/scr/icgaxes.key - + Valdes, January 13, 1987 + 1. When setting sample ranges with the cursor the range limits are now + rounded to the nearest integer only if the x values are integers. + Previously it always rounded even if the data were not integers. + 2. Modified to use system page procedure for printing help. + 3. Revised the help file and included the graph axes help in the same + file since it is now paged. The separate axes help file was deleted. + +pkg$xtools/icfit/icgcolon.gx + Valdes, October 7, 1986 + 1. It is no longer possible to set naverage to 0 which causes ICFIT + to crash. A message is now printed telling the user that 0 is + not a legal value. This error is present in V2.3 and earlier. + +pkg$xtools/icfit/icgdelete.gx +pkg$xtools/icfit/icgundelete.gx + Valdes, September 8, 1986 + 1. Procedures were defined as function but used as subroutines. The + function declarations were removed. Found during the Alliant port. + +pkg$xtools/icfit/icgfit.gx +noao$onedspec/identify/icfit/icgfit.gx + Valdes, August 21, 1986 + 1. When defining sample ranges interactively with the cursor the + new sample string was appended to the previous string without + a leading space and with a trailing space. This was fine if + the sample was defined only interactively or only explicitly + as a string. However, appending an interactive sample to one + the user types in (without a trailing blank) is an error. + Changed the interactive appending to put a leading blank and + no trailing blank. + +noao$lib/src/icgfit.key + Valdes, August 20, 1986 + 1. The key file listed :lowreject and :highreject instead of the + correct :low_reject and :high_reject. The key file was fixed. + +==================================== +Version 2.3 Release, August 18, 1986 +==================================== + +icfit$: Valdes, August 11, 1986 + 1. Reorganized package to have separate objects for each procedure. + This allows loading only the procedures of the desired datatype. + +icfit$icgfit.gx: Valdes, August 7, 1986 + 1. The 'c' key was using a fixed format inappropriate for some types + of data. The formats where changed to general %g format. + +icfit$icgfit.gx: Valdes, August 7, 1986 + 1. A bug in the generic code was causing a double to be + passed to gt_setr which caused the windowing to be wrong. + This bug appeared only in the SUN. + 2. A bug in writing the current key definition with the 'g' key was + fixed. This bug appeared only in the SUN. + +icfit: Valdes, July 3, 1986 + 1. New ICFIT package. + +icfit$icggraph.gx: Valdes, April 28, 1986 + 1. Fixed bug in icggraph.gx: + real $tcveval ---> PIXEL $tcveval + +icfit$icgfit.gx,icgfit2.x,icgcolon.x: Valdes, April 7, 1986 + 1. Fixed use of STRIDX with a character constant to STRIDXS. + 2. Fixed problem with colon usage for ":sample" and ":function" + +icfit: Valdes, Mar 13, 1986: + 1. ICFIT package converted to generic form. The package now has entries + for both single precision and double precision data. It uses the new + curfit math library which now has double precision entries as well. + The external names of the single precision procedures are unchanged. +====== +Release 2.2 +====== +From Valdes Dec 30 , 1985 + +1. Setting of sample ranges by cursor was integer truncating giving the +funny result that if the cursor was set at 4.99 the sample limit was 4. +This has been changed so that the sample limit is rounded to the nearest +integer. +------ +From Valdes Nov 20 , 1985 + +1. New procedure ICG_FIT2 added. This procedure does all graphics +open and closes and has cl parameters "graphics", "plots", and "cursor". +This will eventually phase out ICG_FIT. + +2. Procedures modified to use an array of GTOOLS pointers instead of +keeping them in separate variables. This allows easy expansion to add +additional graph formats. +------ +From Valdes Oct 17 , 1985 + +1. Graphing the zero line was removed from icggraph.x because the line +interfered with fitting data near zero. +------ +From Valdes Oct 4, 1985 + +1. The package was modified to add high and low rejection and to iterate +the rejection algorithm. + +2. Procedure icg_params was add to label the graphs with the fitting +parameters. +.endhelp |