aboutsummaryrefslogtreecommitdiff
path: root/sys/gio/ncarutil/autograph/agdflt.bd
diff options
context:
space:
mode:
Diffstat (limited to 'sys/gio/ncarutil/autograph/agdflt.bd')
-rw-r--r--sys/gio/ncarutil/autograph/agdflt.bd414
1 files changed, 414 insertions, 0 deletions
diff --git a/sys/gio/ncarutil/autograph/agdflt.bd b/sys/gio/ncarutil/autograph/agdflt.bd
new file mode 100644
index 00000000..ddbde9a1
--- /dev/null
+++ b/sys/gio/ncarutil/autograph/agdflt.bd
@@ -0,0 +1,414 @@
+C +NOAO
+C This block data has been rewritten as a run time initialization
+C subroutine (see file agdflt.f). This original block data file
+C is retained for reference only.
+C -NOAO
+C
+C ---------------------------------------------------------------------
+C
+ BLOCK DATA AGDFLT
+C
+C The block data subroutine AGDFLT defines the default values of those
+C AUTOGRAPH parameters which can be declared in a DATA statement. See
+C AGINIT for code initializing other AUTOGRAPH parameters.
+C
+C Following are declarations of all the AUTOGRAPH common blocks.
+C
+C The following common block contains the AUTOGRAPH control parameters,
+C all of which are real. If it is changed, all of AUTOGRAPH (especially
+C the routine AGSCAN) must be examined for possible side effects.
+C
+ COMMON /AGCONP/ QFRA,QSET,QROW,QIXY,QWND,QBAC , SVAL(2) ,
+ + XLGF,XRGF,YBGF,YTGF , XLGD,XRGD,YBGD,YTGD , SOGD ,
+ + XMIN,XMAX,QLUX,QOVX,QCEX,XLOW,XHGH ,
+ + YMIN,YMAX,QLUY,QOVY,QCEY,YLOW,YHGH ,
+ + QDAX(4),QSPA(4),PING(4),PINU(4),FUNS(4),QBTD(4),
+ + BASD(4),QMJD(4),QJDP(4),WMJL(4),WMJR(4),QMND(4),
+ + QNDP(4),WMNL(4),WMNR(4),QLTD(4),QLED(4),QLFD(4),
+ + QLOF(4),QLOS(4),DNLA(4),WCLM(4),WCLE(4) ,
+ + QODP,QCDP,WOCD,WODQ,QDSH(26) ,
+ + QDLB,QBIM,FLLB(10,8),QBAN ,
+ + QLLN,TCLN,QNIM,FLLN(6,16),QNAN ,
+ + XLGW,XRGW,YBGW,YTGW , XLUW,XRUW,YBUW,YTUW ,
+ + XLCW,XRCW,YBCW,YTCW , WCWP,HCWP,SCWP ,
+ + XBGA(4),YBGA(4),UBGA(4),XNDA(4),YNDA(4),UNDA(4),
+ + QBTP(4),BASE(4),QMNT(4),QLTP(4),QLEX(4),QLFL(4),
+ + QCIM(4),QCIE(4),RFNL(4),WNLL(4),WNLR(4),WNLB(4),
+ + WNLE(4),QLUA(4) ,
+ + RBOX(6),DBOX(6,4),SBOX(6,4)
+C
+C The following common block contains other AUTOGRAPH variables, both
+C real and integer, which are not control parameters.
+C
+ COMMON /AGORIP/ SMRL , ISLD , MWCL,MWCM,MWCE,MDLA,MWCD,MWDQ ,
+ + INIF
+C
+C The following common block contains other AUTOGRAPH variables, of
+C type character.
+C
+ COMMON /AGOCHP/ CHS1,CHS2
+C
+ CHARACTER*504 CHS1,CHS2
+C
+C The following common blocks contain variables which are required for
+C the character-storage-and-retrieval scheme of AUTOGRAPH.
+C
+ COMMON /AGCHR1/ LNIC,INCH(2,50),LNCA,INCA
+C
+ COMMON /AGCHR2/ CHRA(2000)
+C
+ CHARACTER*1 CHRA
+C
+C ---------------------------------------------------------------------
+C
+C Following are declarations of default values of variables in the
+C AUTOGRAPH common blocks.
+C
+C ---------------------------------------------------------------------
+C
+C QFRA defines the control parameter 'FRAME.', which specifies when, if
+C ever, the EZ... routines are to call FRAME to advance to a new frame.
+C
+ DATA QFRA / 1. /
+C
+C QSET defines the control parameter 'SET.', which determines how the
+C last call to the plot-package routine "SET" is to affect AUTOGRAPH.
+C
+ DATA QSET / 1. /
+C
+C QROW defines the control parameter 'ROW.', which determines how the x
+C and y input arrays (in calls to AGSTUP and AGCURV) are to be used.
+C
+ DATA QROW / 1. /
+C
+C QIXY defines the control parameter 'INVERT.', which, if set non-zero,
+C causes the routines AGSTUP and AGCURV to behave as if the arguments
+C defining the x and y data had been interchanged.
+C
+ DATA QIXY / 0. /
+C
+C QWND defines the control parameter 'WINDOW.', which, if set non-zero,
+C causes curves drawn to be scissored by the edge of the curve window.
+C
+ DATA QWND / 0. /
+C
+C QBAC defines the control parameter 'BACKGROUND.', which can be given
+C any of four values to set up four specific types of plot background.
+C
+ DATA QBAC / 1. /
+C
+C SVAL defines the control parameters 'NULL/1.' and 'NULL/2.', which are
+C used in various ways by AUTOGRAPH.
+C
+ DATA SVAL(1) / 1E36 / , SVAL(2) / 2E36 /
+C
+C XLGF, XRGF, YBGF, and YTGF define the parameter-group 'GRAPH.'; they
+C specify the position of the graph window within the plotter frame.
+C
+ DATA XLGF / 0. / , XRGF / 1. / , YBGF / 0. / , YTGF / 1. /
+C
+C XLGD, XRGD, YBGD, and YTGD define the first four parameters in the
+C group 'GRID.'; they specify the position of the grid window within
+C the graph window.
+C
+ DATA XLGD / .15 / , XRGD / .95 / , YBGD / .15 / , YTGD / .95 /
+C
+C SOGD defines the control parameter 'GRID/SHAPE.', which defines the
+C shape of the grid window.
+C
+ DATA SOGD / 0. /
+C
+C XMIN and XMAX define the control parameters 'X/MIN.' and 'X/MAX.',
+C which determine how minimum and maximum values of x are to be chosen.
+C Null values imply that AUTOGRAPH is to choose real values; non-null
+C values are the actual values to be used (perhaps after rounding).
+C
+ DATA XMIN / 1E36 / , XMAX / 1E36 /
+C
+C QLUX defines the control parameter 'X/LOG.', which is set non-zero to
+C specify that the horizontal axis is to be logarithmic.
+C
+ DATA QLUX / 0. /
+C
+C QOVX defines the control parameter 'X/ORDER.', which is set non-zero
+C to flip the horizontal axis end-for-end.
+C
+ DATA QOVX / 0. /
+C
+C QCEX defines the control parameter 'X/NICE.', which determines which,
+C if either, of the horizontal axes is to have "nice" (rounded) values
+C at its ends.
+C
+ DATA QCEX / -1. /
+C
+C XLOW and XHGH define the control parameters 'X/SMALLEST.' and
+C 'X/LARGEST.'; they come into play only when XMIN and/or XMAX are null
+C and they are non-null, in which case they set limits on the range of
+C x data to be considered when choosing the minimum and/or maximum.
+C
+ DATA XLOW / 1E36 / , XHGH / 1E36 /
+C
+C YMIN and YMAX define the control parameters 'Y/MIN.' and 'Y/MAX.',
+C which determine how minimum and maximum values of y are to be chosen.
+C Null values imply that AUTOGRAPH is to choose real values; non-null
+C values are the actual values to be used (perhaps after rounding).
+C
+ DATA YMIN / 1E36 / , YMAX / 1E36 /
+C
+C QLUY defines the control parameter 'Y/LOG.', which is set non-zero to
+C specify that the horizontal axis is to be logarithmic.
+C
+ DATA QLUY / 0. /
+C
+C QOVY defines the control parameter 'Y/ORDER.', which is set non-zero
+C to flip the horizontal axis end-for-end.
+C
+ DATA QOVY / 0. /
+C
+C QCEY defines the control parameter 'Y/NICE.', which determines which,
+C if either, of the horizontal axes is to have "nice" (rounded) values
+C at its ends.
+C
+ DATA QCEY / -1. /
+C
+C YLOW and YHGH define the control parameters 'Y/SMALLEST.' and
+C 'Y/LARGEST.'; they come into play only when YMIN and/or YMAX are null
+C and they are non-null, in which case they set limits on the range of
+C y data to be considered when choosing the minimum and/or maximum.
+C
+ DATA YLOW / 1E36 / , YHGH / 1E36 /
+C
+C QDAX(i) defines the control parameters 'AXIS/s/CONTROL.' (i=1 implies
+C s='LEFT', i=2 implies s='RIGHT', i=3 implies s='BOTTOM', i=4 implies
+C s='TOP'). Each of these specifies whether or not a given axis will
+C be drawn or not and what liberties may be taken with numeric labels
+C on the axis.
+C
+ DATA QDAX(1)/ 4. / , QDAX(2)/ 4. / , QDAX(3)/ 4. / , QDAX(4)/ 4. /
+C
+C Each QSPA(i) defines a control parameter 'AXIS/s/LINE.', which says
+C whether or not the line portion of a particular axis is to be drawn.
+C
+ DATA QSPA(1)/ 0. / , QSPA(2)/ 0. / , QSPA(3)/ 0. / , QSPA(4)/ 0. /
+C
+C Each PING(i) defines a control parameter 'AXIS/s/INTERSECTION/GRID.',
+C which may be used to move a particular axis to a specified position.
+C
+ DATA PING(1)/1E36/ , PING(2)/1E36/ , PING(3)/1E36/ , PING(4)/1E36/
+C
+C Each PINU(i) defines a control parameter 'AXIS/s/INTERSECTION/USER.',
+C which may be used to move a particular axis to a specified position.
+C
+ DATA PINU(1)/1E36/ , PINU(2)/1E36/ , PINU(3)/1E36/ , PINU(4)/1E36/
+C
+C Each FUNS(i) defines a control parameter 'AXIS/s/FUNCTION.', which is
+C used within a user-supplied version of AGUTOL to select a particular
+C uset-system-to-label-system mapping for a particular axis. The
+C default value selects the identity mapping.
+C
+ DATA FUNS(1)/ 0. / , FUNS(2)/ 0. / , FUNS(3)/ 0. / , FUNS(4)/ 0. /
+C
+C The values of QBTD(i), BASD(i), QMJD(i), QJDP(i), WMJL(i), and WMJR(i)
+C together define the control-parameter group 'AXIS/s/TICKS/MAJOR.',
+C which determines the positioning and appearance of the major ticks on
+C a particular axis.
+C
+ DATA QBTD(1)/1E36/ , QBTD(2)/1E36/ , QBTD(3)/1E36/ , QBTD(4)/1E36/
+ DATA BASD(1)/1E36/ , BASD(2)/1E36/ , BASD(3)/1E36/ , BASD(4)/1E36/
+ DATA QMJD(1)/ 6. / , QMJD(2)/ 6. / , QMJD(3)/ 6. / , QMJD(4)/ 6. /
+ DATA QJDP(1)/1E36/ , QJDP(2)/1E36/ , QJDP(3)/1E36/ , QJDP(4)/1E36/
+ DATA WMJL(1)/ 0. / , WMJL(2)/ 0. / , WMJL(3)/ 0. / , WMJL(4)/ 0. /
+ DATA WMJR(1)/.015/ , WMJR(2)/.015/ , WMJR(3)/.015/ , WMJR(4)/.015/
+C
+C The values of QMND(i), QNDP(i), WMNL(i), and WMNR(i) together define
+C the control-parameter group 'AXIS/s/TICKS/MINOR.', which determines
+C the positioning and appearance of the major ticks on a particular
+C axis.
+C
+ DATA QMND(1)/1E36/ , QMND(2)/1E36/ , QMND(3)/1E36/ , QMND(4)/1E36/
+ DATA QNDP(1)/1E36/ , QNDP(2)/1E36/ , QNDP(3)/1E36/ , QNDP(4)/1E36/
+ DATA WMNL(1)/ 0. / , WMNL(2)/ 0. / , WMNL(3)/ 0. / , WMNL(4)/ 0. /
+ DATA WMNR(1)/.010/ , WMNR(2)/.010/ , WMNR(3)/.010/ , WMNR(4)/.010/
+C
+C The values of QLTD(i), QLED(i), QLFD(i), QLOF(i), QLOS(i), DNLA(i),
+C WCLM(i), and WCLE(i) together define the control-parameter group
+C 'AXIS/s/NUMERIC.', which determines the positioning and appearance of
+C the numeric labels on a particular axis.
+C
+ DATA QLTD(1)/1E36/ , QLTD(2)/ 0./ , QLTD(3)/1E36/ , QLTD(4)/ 0./
+ DATA QLED(1)/1E36/ , QLED(2)/1E36/ , QLED(3)/1E36/ , QLED(4)/1E36/
+ DATA QLFD(1)/1E36/ , QLFD(2)/1E36/ , QLFD(3)/1E36/ , QLFD(4)/1E36/
+ DATA QLOF(1)/ 0. / , QLOF(2)/ 0. / , QLOF(3)/ 0. / , QLOF(4)/ 0. /
+ DATA QLOS(1)/ 90./ , QLOS(2)/ 90./ , QLOS(3)/ 90./ , QLOS(4)/ 90./
+ DATA DNLA(1)/.015/ , DNLA(2)/.015/ , DNLA(3)/.015/ , DNLA(4)/.015/
+ DATA WCLM(1)/.015/ , WCLM(2)/.015/ , WCLM(3)/.015/ , WCLM(4)/.015/
+ DATA WCLE(1)/.010/ , WCLE(2)/.010/ , WCLE(3)/.010/ , WCLE(4)/.010/
+C
+C QODP defines the control parameter 'DASH/SELECTOR.', the sign of which
+C determines which set of dash patterns is used by EZMY and EZMXY (the
+C alphabetic set or the user-specified set); if the user-specified set
+C is selected, the magnitude of QODP determines how many of them are to
+C be used.
+C
+ DATA QODP / 1. /
+C
+C QCDP defines the control parameter 'DASH/LENGTH.', which specifies the
+C assumed length of dash patterns tendered to AUTOGRAPH.
+C
+ DATA QCDP / 8. /
+C
+C WOCD and WODQ define the control parameters 'DASH/CHARACTER.' and
+C 'DASH/DOLLAR-QUOTE.', which specify the widths of characters used in
+C character-string dash patterns.
+C
+ DATA WOCD / .010 / , WODQ / .010 /
+C
+C QDSH defines the control-parameter group 'DASH/PATTERN.'. Each value,
+C if positive, defines a binary dash pattern, and, if negative, serves
+C as an identifier in retrieving a character-string dash pattern.
+C
+ DATA QDSH / 26*65535. /
+C
+C QDLB defines the control parameter 'LABEL/CONTROL.', which specifies
+C what may be done with informational labels in response to overlap
+C problems.
+C
+ DATA QDLB /2./
+C
+C QBIM defines the control parameter 'LABEL/BUFFER/LENGTH.' and must
+C be equal to the second dimension of the array FLLB.
+C
+ DATA QBIM / 8. /
+C
+C QBAN defines the control parameter 'LABEL/NAME.'; its value is really
+C a pointer into the label list. The default value, zero, means that
+C the pointer has not been set.
+C
+ DATA QBAN / 0. /
+C
+C QLLN defines the control parameter 'LINE/MAXIMUM.' - the assumed
+C maximum length of character strings intended for use as the text of a
+C line of a label.
+C
+ DATA QLLN /40./
+C
+C TCLN defines the control parameter 'LINE/TERMINATOR.' - which is used
+C to mark the end of character strings intended for use as the text of a
+C line of a label. It is initialized in AGINIT.
+C
+C QNIM defines the control parameter 'LINE/BUFFER/LENGTH.' and must be
+C equal to the second dimension of FLLN.
+C
+ DATA QNIM / 16. /
+C
+C QNAN defines the control parameter 'LINE/NUMBER.'; its value is really
+C a pointer into the line list. The default value, zero, says that the
+C pointer has not been set.
+C
+ DATA QNAN / 0. /
+C
+C (FLLB(I,1),I=1,10) and (FLLN(I,1),I=1,6) define the label to the left
+C of the grid. The name, in FLLB(1,1), and the line text, in FLLN(4,1),
+C must be filled in by AGINIT.
+C
+ DATA FLLB( 1,1)/ 0./ , FLLB( 2,1)/ 0./ , FLLB( 3,1)/ 0./ ,
+ + FLLB( 4,1)/ .5/ , FLLB( 5,1)/-.015/ , FLLB( 6,1)/ 0./ ,
+ + FLLB( 7,1)/ 90./ , FLLB( 8,1)/ 0./ , FLLB( 9,1)/ 1./ ,
+ + FLLB(10,1)/ 1./ , FLLN( 1,1)/+100./ , FLLN( 2,1)/ 0./ ,
+ + FLLN( 3,1)/ .015/ , FLLN( 4,1)/ -2./ , FLLN( 5,1)/ 1./ ,
+ + FLLN( 6,1)/ 0./
+C
+C (FLLB(I,2),I=1,10) and (FLLN(I,2),I=1,6) define the label to the right
+C of the grid. The name, in FLLB(1,2), and the line text, in FLLN(4,2),
+C must be filled in by AGINIT.
+C
+ DATA FLLB( 1,2)/ 0./ , FLLB( 2,2)/ 0./ , FLLB( 3,2)/ 1./ ,
+ + FLLB( 4,2)/ .5/ , FLLB( 5,2)/+.015/ , FLLB( 6,2)/ 0./ ,
+ + FLLB( 7,2)/ 90./ , FLLB( 8,2)/ 0./ , FLLB( 9,2)/ 1./ ,
+ + FLLB(10,2)/ 2./ , FLLN( 1,2)/-100./ , FLLN( 2,2)/ 0./ ,
+ + FLLN( 3,2)/ .015/ , FLLN( 4,2)/ -3./ , FLLN( 5,2)/ 0./ ,
+ + FLLN( 6,2)/ 0./
+C
+C (FLLB(I,3),I=1,10) and (FLLN(I,3),I=1,6) define the label below the
+C grid. The name, in FLLB(1,3), and the line text, in FLLN(4,3), must
+C be filled in by AGINIT.
+C
+ DATA FLLB( 1,3)/ 0./ , FLLB( 2,3)/ 0./ , FLLB( 3,3)/ .5/ ,
+ + FLLB( 4,3)/ 0./ , FLLB( 5,3)/ 0./ , FLLB( 6,3)/-.015/ ,
+ + FLLB( 7,3)/ 0./ , FLLB( 8,3)/ 0./ , FLLB( 9,3)/ 1./ ,
+ + FLLB(10,3)/ 3./ , FLLN( 1,3)/-100./ , FLLN( 2,3)/ 0./ ,
+ + FLLN( 3,3)/ .015/ , FLLN( 4,3)/ -1./ , FLLN( 5,3)/ 1./ ,
+ + FLLN( 6,3)/ 0./
+C
+C (FLLB(I,4),I=1,10) and (FLLN(I,4),I=1,6) define the label above the
+C grid. The name, in FLLB(1,4), and the line text, in FLLN(4,4), must
+C be filled in by AGINIT.
+C
+ DATA FLLB( 1,4)/ 0./ , FLLB( 2,4)/ 0./ , FLLB( 3,4)/ .5/ ,
+ + FLLB( 4,4)/ 1./ , FLLB( 5,4)/ 0./ , FLLB( 6,4)/+.020/ ,
+ + FLLB( 7,4)/ 0./ , FLLB( 8,4)/ 0./ , FLLB( 9,4)/ 1./ ,
+ + FLLB(10,4)/ 4./ , FLLN( 1,4)/+100./ , FLLN( 2,4)/ 0./ ,
+ + FLLN( 3,4)/ .020/ , FLLN( 4,4)/ -3./ , FLLN( 5,4)/ 0./ ,
+ + FLLN( 6,4)/ 0./
+C
+C Certain secondary parameters must be initialized to prevent bombing.
+C
+ DATA QBTP(1)/ 0./ , QBTP(2)/ 0./ , QBTP(3)/ 0./ , QBTP(4)/ 0./
+ DATA BASE(1)/ 0./ , BASE(2)/ 0./ , BASE(3)/ 0./ , BASE(4)/ 0./
+ DATA QMNT(1)/ 0./ , QMNT(2)/ 0./ , QMNT(3)/ 0./ , QMNT(4)/ 0./
+ DATA QLTP(1)/ 0./ , QLTP(2)/ 0./ , QLTP(3)/ 0./ , QLTP(4)/ 0./
+ DATA QLEX(1)/ 0./ , QLEX(2)/ 0./ , QLEX(3)/ 0./ , QLEX(4)/ 0./
+ DATA QLFL(1)/ 0./ , QLFL(2)/ 0./ , QLFL(3)/ 0./ , QLFL(4)/ 0./
+ DATA QCIM(1)/ 0./ , QCIM(2)/ 0./ , QCIM(3)/ 0./ , QCIM(4)/ 0./
+ DATA QCIE(1)/ 0./ , QCIE(2)/ 0./ , QCIE(3)/ 0./ , QCIE(4)/ 0./
+ DATA RFNL(1)/ 0./ , RFNL(2)/ 0./ , RFNL(3)/ 0./ , RFNL(4)/ 0./
+ DATA QLUA(1)/ 0./ , QLUA(2)/ 0./ , QLUA(3)/ 0./ , QLUA(4)/ 0./
+C
+C SMRL and ISLD are set by the routine AGINIT (which see, below).
+C
+C MWCL, MWCM, MWCE, MDLA, MWCD, and MWDQ are the minimum widths of label
+C characters, mantissa characters, exponent characters, label-to-axis
+C distances, dash-pattern characters, and dash-pattern spaces, respect-
+C ively (in the plotter coordinate system).
+C
+ DATA MWCL /8/, MWCM /8/, MWCE /8/, MDLA /8/, MWCD /8/, MWDQ /8/
+C
+C INIF is an initialization flag, set non-zero to indicate that the
+C routine AGINIT has been executed to set the values of AUTOGRAPH
+C parameters which, for one reason or another, cannot be preset by
+C this block data routine.
+C
+ DATA INIF / 0 /
+C
+C CHS1 and CHS2 are used within AUTOGRAPH when manipulating character
+C strings retrieved by calls to AGGTCH. They need not be preset.
+C
+C LNIC is the second dimension of the array (INCH) which holds an index
+C of the character strings stored by AGSTCH.
+C
+ DATA LNIC / 50 /
+C
+C INCH is an index of character strings currently stored in CHRA. Each
+C entry has the following format:
+C
+C INCH(1,I), if non-zero, is the index, in the array CHRA, of the
+C first character of the Ith character string.
+C
+C INCH(2,I) is the length of the Ith character string.
+C
+ DATA (INCH(1,I),I=1,50) / 50*0 /
+ DATA (INCH(2,I),I=1,50) / 50*0 /
+C
+C LNCA is the size of the array (CHRA) in which AGSTCH stores character
+C strings.
+C
+ DATA LNCA / 2000 /
+C
+C INCA is the index of the last character used in CHRA.
+C
+ DATA INCA / 0 /
+C
+C CHRA holds character strings stored by AGSTCH. It need not be pre-set
+C to anything.
+C
+ END