1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
|
===============================================
Distortion Correction in HST FITS Files - DRAFT
===============================================
.. abstract::
:author: Warren Hack, Andy Fruchter, Perry Greenfield, Nadezhda Dencheva
:date: 18 Sept 2012
A convention for storing distortion information in HST images was developed
and implemented in two software packages - PyWCS and STWCS. These changes
allow the development of a WCS based version of Multidrizzle and image
alignment software. The distribution of WCS solutions is discussed.
Introduction
============
Calibration of the HST Advanced Camera for Surveys (HST/ACS) distortion requires the use
of several components to the distortion correction; namely, polynomial coefficients, a
lookup table for non-polynomial terms, a time-dependent skew, and a detector defect
correction. Each of these terms has been derived as part of the calibration effort to address
separate aspects of the distortion that affects ACS observations. Ideally, each would be applied
independently in the same manner used for deriving the original calibration reference information,
with the time-dependent skew being folded into the other terms. However, the software for
applying the distortion models does not support this option. In fact, there is no clear
accepted standard for specifying distortion corrections in FITS headers. Instead, there are
several separate proposals for specifying aspects of the distortion, but none by themselves
allows us to fully specify the distortion already calibrated for ACS, let alone in a modular,
efficient manner.
This paper describes a composite implementation of a select set of proposed standards which
supports all aspects of the distortion models for HST instruments without breaking any of the
conventions/standards. The rules for merging the proposed standards allow software to be defined
to apply each aspect of this proposal as a separate option while defining the requirements
necessary to allow them to work together when specified in the header. As a result, the separate
components essentially become tools where only those conventions appropriate to the observation
can be used as needed.
Problems Introduced by the HST/ACS Distortion
=============================================
All calibrations for HST observations get recorded and applied through the use of
reference files, separate files which describe some calibration. The geometric
distortion typically applied to HST images gets recorded as a polynomial component
in one reference file, and a pixel-by-pixel correction to the polynomial solution
in a separate reference file. This method allows the distortion to be corrected to
an accuracy of better than 0.1 pixels. However, this method requires the user to
obtain the reference files themselves anytime they want to reprocess the data. The
size of these reference files (up to 200Mb) makes this an expensive requirement for
the end user. The alternative would be to include the necessary specification of the
distortion model in the header of the image itself, as long as it can be done in a
manner that does not dramatically increase the size of the image itself. For reference,
a typical calibrated ACS/WFC image requires a 168Mb file. Thus, we needed an alternative
to separate reference files which can be implemented in a very efficient manner within
the image's FITS headers.
The calibrations also represent separate aspects of the detector and the distortion,
aspects which logically should remain as separate descriptions in the header. The pixels
for each CCD do not have the same size across the entire chip. The ACS/WFC CCDs manufacturing
process resulted in the pixels having different sizes every 68.3 columns, and can be represented
most efficiently and accurately by a 1-D correction that gets applied to every row in the chip.
This detector level characterization affects all images readout from the CCD regardless of any
additional distortion applied to the field of view. Logically, this effect should be kept as a
separate component of the distortion model that gets applied prior to correcting for any other
distortion. This represents an example of an effect that is best applied sequentially to the image data.
Additional distortions come as a result of the effect of the optics on the field of view.
These are generally described by low-order polynomials for most instruments, although for
ACS, an additional non-polynomial correction needed to be taken into account as well.
Fortunately, the non-polynomial correction can sub-sampled enough to make it practical
to include in the image headers directly, a correction of up to a quarter of a pixel in some
areas of the detector. Both components need to be applied to the data in order to align images
well enough for subsequent data analysis or cosmic-ray rejection.
These corrections could be combined into a single look-up table, yet it would come at the
cost of additional errors which may not allow the remaining data analysis or cosmic-ray
rejection to actually succeed. We also have some instruments where there is only a polynomial
component, requiring the development of support for a polynomial correction and a look-up
table anyway.
These requirements on the application of the calibrations to HST data leave us with no
alternative within current FITS standards. As a result, we developed this set of rules
which allow us to take advantage of the most appropriate conventions for each separate
component of the distortion model and combine them in an efficient manner which eliminates
the need for external reference data.
SIP Convention
==============
Current implementations of distortion models in FITS headers have been limited to simply
describing polynomial models. The prime example of this would be the implementation of SIP
in WCSTOOLS and DS9 as used for Spitzer data [SIPConvention]_. The keywords used for the SIP standard are:
::
CTYPE1 = 'RA---TAN-SIP'
CTYPE2 = 'DEC--TAN-SIP'
CDi_j / Linear terms of distortion plus scale and orientation
A_ORDER = n / polynomial order, axis 1, detector to sky
A_i_j / High order coefficients for X axis
A_DMAX = 0.0 / [pixel] maximum correction along axis 1
B_ORDER = m / polynomial order, axis 2, detector to sky
B_i_j / High order coefficients for axis 2
B_DMAX = 0.0 / [pixel] maximum correction along axis 2
SIPREFi = 0.0 / Origin of distortion model along axis i
SIPSCLi = 1.0 / Scale term for axis i
The SIP convention retains the use of the current definition of the CD matrix where the
linear terms of the distortion model are folded in with the orientation and scale at the
reference point for each chip to provide the best linear approximation to the distortion
available. The SIP convention gets applied to the input pixel positions by applying the
higher-order coefficients A_i_j, B_i_j, then by applying the CD matrix and adding the CRVAL
position to get the final world coordinates.
This convention was created from the original form of the FITS Distortion Paper standards, but the
FITS Distortion Paper proposal since changed to use a different set of keywords and conventions.
A sample ACS/WFC SCI header can be found in :ref:`Appendix1` to illustrate how these
keywords actually get populated for an image. The current implementation does not
take advantage of the A_DMAX, B_DMAX, SIPREFi or SIPSCLi keywords, so these keywords
are not written out to the SCI header.
FITS Distortion Proposal
=========================
The current FITS Distortion Paper conventions [DistortionPaper]_ provide a mechanism for specifying either a lookup table
or polynomial model for the distortion of each axis. The standard states in Section 2.1:
``Note that the prior distortion functions,, operate on pixel coordinates (i.e. p
rather than p− r ), and that the independent variables of the distortion functions
are the uncorrected pixel or intermediate pixel coordinates. That is, for example,
we do not allow the possibility of``
.. math::
q'_{3} = q_{3} + \delta_{q_{3}}(q'_{1},q'_{2})
The keywords used for describing these corrections use the syntax given in Table 2 of the FITS Distortion Paper.
For our purposes, the keywords of interest are those related to lookup tables; namely,
::
CPDISja string 2.4.1 distortion code new Prior distortion function type.
DPja record 2.4.2 distortion parameter new Parameter for a prior distortion
function, for use in an image header
This syntax only provides the option to specify one correction at a time for each
axis of the image. This precludes being able to use this convention to specify both
a lookup table and a polynomial model at the same time for the same axis. It does not
state what should be done if the polynomial has been specified using a different
convention, for example, the SIP convention. Thus, SIP and FITS Distortion Paper should not be
seen as mutually exclusive. In fact, they may work together rather naturally since the
SIP and FITS Distortion Paper conventions both assume the corrections will work on the input pixel
and add to the output frame.
The sample header in :ref:`Appendix1` shows how these keywords get populated for
an actual reference file; specifically, an NPOLFILE as described in the next section.
NPOLFILE reference File Format
==============================
The reference file to be used for this correction will not have the same format
as the original DGEOFILE as used by ACS and WFPC2 as that large of a reference
file would more than double the size of each input image since the reference
file gets folded into each file. Instead, a sub-sampled array of corrections will
be stored in the new reference file, with ACS using a 65 x 33 array for each ACS/WFC
chip.
.. figure:: /images/npol_vector_text.png
:width: 95 %
:alt: ACS/WFC F475W NPOLFILE corrections
:align: center
This figure illustrates the corrections included in the ACS/WFC F475W NPOLFILE.
This new reference file will be called an **NPOLFILE** in the FITS image header,
so that any original DGEOFILE reference filename can be retained in parallel for
backwards compatibility with the current software. This reference file will also
have a unique suffix, **_npl.fits**, as another means of identifying it as a new r
eference file separate from the current DGEOFILE files. The header for this new
reference file also remains very simple, as illustrated in :ref:`Appendix2`.
Distortion residuals have been calibrated for ACS by looking at the average correction that
still needs to be applied over each 64x64 pixel section of each chip after applying
the polynomial coefficients. This
would normally result in a 64 x 32 array of residuals for each 4096 x 2048 chip.
These arrays, though, need to be expanded by one value in each dimension to support
interpolation all the way to the edge of each chip resulting in 65 x 33 arrays of
distortion correction data. Applying these corrections starts by reading the two 65 x 33
arrays into memory with each input ACS/WFC chip WCS (one for
X offsets and one for Y offsets). Bi-linear interpolation based on the input pixel
position then gets used on-the-fly to extract the final offset from this reference
file. Initial versions of these sub-sampled NPOLFILE reference files for ACS have
been derived from the current full-size DGEOFILEs, and testing indicates residuals
only on the order of 0.02 pixels or less remain when compared to Jay's results.
Detector To Image Correction
============================
The last element of the distortion which remains to be described is the fixed column
(or row) width correction. This needs to be applied as a correction to the input pixel
position and the output of this correction is to be used as input to the polynomial and
non-polynomial distortion corrections.
The adopted implementation is based on the FITS Distortion Paper lookup table convention. It is assumed
that the detector to image correction is the same for all chips but it can be extended
to arbitrary number of chips and extensions if necessary.
For ACS the correction is stored as an image extension with one row. Each element in
the row specifies the correction in pixels for every pixel in the column (or row) in
the science extension as predetermined by the calibration teams who would be responsible
for creating the reference files. For ACS the correction is in the X direction and for
WFPC2 - in the Y direction. The following new keywords are added to the header of each
science extension of a science file:
::
'D2IMFILE' = "string - name of reference file to be used for creating the lookup table"
'AXISCORR' = "integer (1 or 2) - axis to which the det2im correction is applied"
'D2IMEXT' = "string - name of reference file which was last used to create the lookup table"
'D2IMERR' = (optional)" float - maximum value of the correction"
'D2IMFILE' is used by UPDATEWCS as a flag that a reference file with this correction exists
and an extension should be created. UPDATEWCS records the name of the reference file used
for the lookup table extension to a keyword D2IMEXT in the primary header. It also populates
keyword 'AXISCORR' based on whether this is a row or column correction. The lookup table
extension has an 'EXTNAME' value of 'D2IMARR'.
'AXISCORR' is used as an indication of the axis to which the correction should be applied
(1 - 'X' Axis, 2- 'Y' axis). 'D2IMEXT' stores the name of the reference file used by
UPDATEWCS to create a D2IMARR extension. If 'D2IMEXT' is present in the 'SCI' extension
header and is different from the current value of D2IMFILe in the primary header, the
correction array in D2IMARR is updated. The optional keyword 'D2IMERR' allows a user to
ignore this correction without modifying other header keywords by passing a parameter to
the software. The HSTWCS class accepts a parameter 'minerr' which specifies the minimum
value a distortion correction must have in order to be applied. If 'minerr' is larger than
'D2IMERR' the correction is not applied.
Detector To Image Reference File
================================
An entirely new reference file needs to be generated in order to specify this correction
for each affected instrument. This reference file only contains a single array of offsets
corresponding to the 1-D correction to be applied. Header keywords in the reference file
then specify what axis gets this correction. As a result, this new reference file remains
small enough to easily be added to an input image without significant change in size. An
initial **D2IMFILE** for ACS has been generated for testing with a sample header provided in
:ref:`Appendix3`.
.. figure:: /images/d2im_bar.png
:width: 95 %
:alt: ACS/WFC F475W D2IMFILE corrections
:align: center
This figure illustrates the corrections included in the first 246 columns of
the ACS/WFC F475W D21IMFILE.
The WCS for this correction describes the extension as a 1-D image, even though it will
be applied to a 2-D image. This keeps it clear that the same correction gets applied to
all rows(columns) without interpolation. The header specifies which axis this correction
applies to through the use of the AXISCORR keyword. The WCS keywords in the header of the
D2IMARR extension specifies the transformation between pixel coordinates and lookup table
position as if the lookup table were an image itself with 1-based positions (starting pixel
is at a position of (1,1)). The value at that lookup table position then gets used to correct
the original input pixel position.
Merging Of The Conventions
==========================
The full implementation of all these elements ends up merging the SIP, DET2IM and FITS Distortion Paper
conventions to create a new version of the figure from the FITS Distortion Paper which illustrates the conversion
of detector coordinates to world coordinates. This implementation works in the following way:
#. Apply detector to image correction (DET2IM) to input pixel values
#. Apply SIP coefficients to DET2IM-corrected pixel values
#. Apply lookup table correction to DET2IM-corrected pixel values
#. Add the results of the SIP and lookup table corrections
#. Apply the WCS transformation in the CD matrix to the summed results to get the intermediate world coordinates
#. Add the CRVAL keyword values to the transformed positions to get the final world coordinates
The computations to perform these steps can be described approximately using:
.. math:: (x',y') &= DET2IM(x,y)
.. math:: \binom{u'}{v'} &= \binom{x' - CRPIX1}{y' - CRPIX2}
.. math:: \left( \begin{array}{ll}
\alpha \\
\delta \\
\end{array} \right) &=
\left( \begin{array}{ll}
CRVAL1 \\
CRVAL2\\
\end{array} \right) +
\left( \begin{array}{cc}
CD11 & CD12 \\
CD21 & CD22\\
\end{array} \right)
\left( \begin{array}{ll}
u' + f(u',v') + LT_x(x',y') \\
v' + g(u',v') + LT_y(x',y') \\
\end{array} \right)
where f(u',v') and g(u',v') represent the polynomial distortion correction specified as
.. math:: f(u',v') = \sum_{p+q=2}^{AORDER} A_{pq} {u'}^{p} {v'}^{q}
\\
g(u',v') = \sum_{p+q=2}^{BORDER} B_{pq} {u'}^{p} {v'}^{q}
where
* x', y' are the initial coordinates x,y with the 68th column correction applied
through the DET2IM convention
* u',v' are the DET2IM-corrected coordinates relative to CRPIX1,CRPIX2
* :math:`LT_{x}, LT_{y}` is the residual distortion in the lookup tables
written to the header using the FITS Distortion Paper lookup table convention
* A, B are the SIP coefficients specified using the SIP convention
These equations do not take into account the deprojection from the tangent plane to
sky coordinates. The complete Detector To Sky Coordinate Transformation is based on
the CTYPE keyword.
.. figure:: /images/pipeline.png
Coordinate Transformation Pipeline
.. [DistortionPaper] Calabretta M. R., Valdes F. G., Greisen E. W., and Allen S. L., 2004,
"Representations of distortions in FITS world coordinate systems",[cited 2012 Sept 18],
Available from: http://www.atnf.csiro.au/people/mcalabre/WCS/dcs_20040422.pdf
.. [SIPConvention] Shupe D.L., Hook R.N., 2008, "The SIP Convention for Representing Distortion in FITS Image
Headers", [cited 2012 Sept 18], Available from: http://fits.gsfc.nasa.gov/registry/sip.html
.. _Appendix1:
**********************************
Appendix 1 - Sample ACS/WFC Image
**********************************
The WCS of a single chip from an ACS/WFC exposure illustrates how the SIP keywords are
populated based on the coefficients from the external IDCTAB reference file. In addition,
this header includes the keywords referring to additional distortion corrections
related to non-polynomial corrections from the NPOLFILE and to column-width corrections from
the D2IMFILE. This sample illustrates how all three corrections can be specified at the
same time in a FITS header using our rules for combining the SIP WCS convention and
FITS Distortion Paper proposed syntax, while also using FITS WCS Paper I alternate WCS
standards to maintain a record of the WCS information prior to being updated/recomputed to
use the new reference information. The old WCS gets stored using WCS key 'O' and 'WCSNAMEO' = 'OPUS'
to indicate it was originally computed by OPUS, the HST pipeline system.
FITS File extensions
--------------------
The FITS file for this ACS/WFC image now contains extra extensions for the NPOLFILE and D2IMFILE
corrections.
::
Filename: jbf401p8q_flc.fits
No. Name Type Cards Dimensions Format
0 PRIMARY PrimaryHDU 261 () int16
1 SCI ImageHDU 184 (4096, 2048) float32
2 ERR ImageHDU 55 (4096, 2048) float32
3 DQ ImageHDU 47 (4096, 2048) int16
4 SCI ImageHDU 183 (4096, 2048) float32
5 ERR ImageHDU 55 (4096, 2048) float32
6 DQ ImageHDU 47 (4096, 2048) int16
7 D2IMARR ImageHDU 12 (4096,) float32
8 WCSDVARR ImageHDU 37 (65, 33) float32
9 WCSDVARR ImageHDU 37 (65, 33) float32
10 WCSDVARR ImageHDU 37 (65, 33) float32
11 WCSDVARR ImageHDU 37 (65, 33) float32
12 WCSCORR BinTableHDU 59 14R x 24C [40A, I, 1A, 24A, 24A, 24A, 24A, D, D, D, D, D, D, D, D,
24A, 24A, D, D, D, D, J, 40A, 128A]
The last extension, named WCSCORR, contains a binary table providing a summary of all the WCS
solutions that have been applied to this file and does not act as an active part of the WCS
or its interpretation.
Primary Header
--------------
The PRIMARY header of HST data contains keywords specifying information general to
the entire file, such as what calibration steps were applied and what reference files
should be used. No active WCS keywords (keywords interpreted for coordinate transformations)
are present in the PRIMARY header, but keywords specifying the applicable distortion
reference files can be found in the PRIMARY header. Some keywords describing the
distortion model and when the WCS was updated with the distortion information from the
reference files can also be found in the PRIMARY header. These distortion and WCS
related keywords from the PRIMARY header are::
/ CALIBRATION REFERENCE FILES
IDCTAB = 'jref$v8q1444sj_idc.fits' / image distortion correction table
DGEOFILE= 'jref$qbu16420j_dxy.fits' / Distortion correction image
D2IMFILE= 'jref$v971826mj_d2i.fits' / Column Correction Reference File
NPOLFILE= 'jref$v971826aj_npl.fits' / Non-polynomial Offsets Reference File
UPWCSVER= '1.0.0 ' / Version of STWCS used to updated the WCS
PYWCSVER= '1.11-4.10' / Version of PYWCS used to updated the WCS
DISTNAME= 'jbf401p8q_v8q1444sj-v971826aj-v971826mj'
SIPNAME = 'jbf401p8q_v8q1444sj'
The remainder of the PRIMARY header specifies the general characteristics of the image.
SCI Header Keywords
-------------------
The following keywords only represent the WCS keywords from a sample ACS/WFC SCI header with 4-th order
polynomial distortion correction from the IDCTAB reference file, along with NPOLFILE and
D2IMFILE corrections from the specific reference files used as examples in :ref:`Appendix2`
:ref:`Appendix3`.
::
XTENSION= 'IMAGE ' / IMAGE extension
BITPIX = -32
NAXIS = 2
NAXIS1 = 4096
NAXIS2 = 2048
PCOUNT = 0 / required keyword; must = 0
GCOUNT = 1 / required keyword; must = 1
ORIGIN = 'HSTIO/CFITSIO March 2010'
DATE = '2012-06-13' / date this file was written (yyyy-mm-dd)
INHERIT = T / inherit the primary header
EXTNAME = 'SCI ' / extension name
EXTVER = 1 / extension version number
ROOTNAME= 'jbf401p8q ' / rootname of the observation set
EXPNAME = 'jbf401p8q ' / exposure identifier
BUNIT = 'ELECTRONS' / brightness units
/ WFC CCD CHIP IDENTIFICATION
CCDCHIP = 2 / CCD chip (1 or 2)
/ World Coordinate System and Related Parameters
WCSAXES = 2 / number of World Coordinate System axes
CRPIX1 = 2048 / x-coordinate of reference pixel
CRPIX2 = 1024 / y-coordinate of reference pixel
CRVAL1 = 11.3139376926 / first axis value at reference pixel
CRVAL2 = 42.0159325283 / second axis value at reference pixel
CTYPE1 = 'RA---TAN-SIP' / the coordinate type for the first axis
CTYPE2 = 'DEC--TAN-SIP' / the coordinate type for the second axis
CD1_1 = -7.8194868997837E-06 / partial of first axis coordinate w.r.t. x
CD1_2 = 1.09620231564470E-05 / partial of first axis coordinate w.r.t. y
CD2_1 = 1.14279318521882E-05 / partial of second axis coordinate w.r.t. x
CD2_2 = 8.66885775536641E-06 / partial of second axis coordinate w.r.t. y
LTV1 = 0.0000000E+00 / offset in X to subsection start
LTV2 = 0.0000000E+00 / offset in Y to subsection start
LTM1_1 = 1.0 / reciprocal of sampling rate in X
LTM2_2 = 1.0 / reciprocal of sampling rate in Y
ORIENTAT= 51.66276166150634 / position angle of image y axis (deg. e of n)
RA_APER = 1.133205840898E+01 / RA of aperture reference position
DEC_APER= 4.202747924810E+01 / Declination of aperture reference position
PA_APER = 51.4653 / Position Angle of reference aperture center (de
VAFACTOR= 9.999374411935E-01 / velocity aberration plate scale factor
WCSCDATE= '18:41:12 (13/06/2012)' / Time WCS keywords were copied.
A_0_2 = 2.18045745103211E-06
B_0_2 = -7.2266555836441E-06
A_1_1 = -5.2225148886672E-06
B_1_1 = 6.20296011911662E-06
A_2_0 = 8.54842918202735E-06
B_2_0 = -1.7551668097547E-06
A_0_3 = 8.09354090167772E-12
B_0_3 = -4.2488740853874E-10
A_1_2 = -5.2903025382457E-10
B_1_2 = -7.6098727022982E-11
A_2_1 = -4.4821374838034E-11
B_2_1 = -5.1244088812978E-10
A_3_0 = -4.6755353102513E-10
B_3_0 = 8.48145748580355E-11
A_0_4 = -8.3665541956904E-17
B_0_4 = -2.1662072760964E-14
A_1_3 = -1.5108585176304E-14
B_1_3 = -1.5686763638364E-14
A_2_2 = 3.61252682019403E-14
B_2_2 = -2.6194214315839E-14
A_3_1 = 1.03502537140899E-14
B_3_1 = -2.6915637616404E-15
A_4_0 = 2.32643027828425E-14
B_4_0 = -1.5701287138447E-14
A_ORDER = 4
B_ORDER = 4
IDCSCALE= 0.05
IDCV2REF= 256.6019897460938
IDCV3REF= 302.2520141601562
IDCTHETA= 0.0
OCX10 = 0.001965125839177266
OCX11 = 0.04983026381230307
OCY10 = 0.0502766128737329
OCY11 = 0.001493971240339153
TDDALPHA= 0.246034678162242
TDDBETA = -0.07934489272074734
IDCXREF = 2048.0
IDCYREF = 1024.0
AXISCORR= 1
D2IMEXT = '/grp/hst/cdbs/jref/v971826mj_d2i.fits'
D2IMERR = 0.002770500956103206
WCSNAMEO= 'OPUS '
WCSAXESO= 2
CRPIX1O = 2048
CRPIX2O = 1024
CDELT1O = 1
CDELT2O = 1
CUNIT1O = 'deg '
CUNIT2O = 'deg '
CTYPE1O = 'RA---TAN-SIP'
CTYPE2O = 'DEC--TAN-SIP'
CRVAL1O = 11.3139376926
CRVAL2O = 42.0159325283
LONPOLEO= 180
LATPOLEO= 42.0159325283
RESTFRQO= 0
RESTWAVO= 0
CD1_1O = -7.81948731152E-06
CD1_2O = 1.09620228331E-05
CD2_1O = 1.14279315609E-05
CD2_2O = 8.66885813904E-06
WCSNAME = 'IDC_v8q1444sj'
CPERROR1= 0.0 / Maximum error of NPOL correction for axis 1
CPDIS1 = 'Lookup ' / Prior distortion funcion type
DP1 = 'EXTVER: 1' / Version number of WCSDVARR extension containing lookup d
DP1 = 'NAXES: 2' / Number of independent variables in distortion function
DP1 = 'AXIS.1: 1' / Axis number of the jth independent variable in a distort
DP1 = 'AXIS.2: 2' / Axis number of the jth independent variable in a distort
CPERROR2= 0.0 / Maximum error of NPOL correction for axis 2
CPDIS2 = 'Lookup ' / Prior distortion funcion type
DP2 = 'EXTVER: 2' / Version number of WCSDVARR extension containing lookup d
DP2 = 'NAXES: 2' / Number of independent variables in distortion function
DP2 = 'AXIS.1: 1' / Axis number of the jth independent variable in a distort
DP2 = 'AXIS.2: 2' / Axis number of the jth independent variable in a distort
NPOLEXT = 'jref$v971826aj_npl.fits'
All keywords related to the exposure itself, such as readout pattern, have been deleted
from this SCI header listing for the sake of brevity.
.. _Appendix2:
*************************************
Appendix 2 - NPOLFILE Example
*************************************
The NPOLFILE reference file format includes a PRIMARY header describing what kind of
image should be corrected by this file, along with extensions containing the corrections
for each chip.
FITS File Extensions
--------------------
A sample NPOLFILE applicable to ACS/WFC F475W images has the FITS extensions::
Filename: /grp/hst/cdbs/jref/v971826aj_npl.fits
No. Name Type Cards Dimensions Format
0 PRIMARY PrimaryHDU 35 () int16
1 DX ImageHDU 180 (65, 33) float32
2 DY ImageHDU 215 (65, 33) float32
3 DX ImageHDU 215 (65, 33) float32
4 DY ImageHDU 215 (65, 33) float32
The extensions with the name 'DX' provide the corrections in X for each of the
ACS/WFC's 2 chips, while the 'DY' extensions provide the corrections in Y for each chip.
Primary Header
--------------
The PRIMARY header of this file only includes the minimum information necessary to describe
what exposures should be corrected by this reference file and how it was generated. A full
listing of the PRIMARY header includes::
SIMPLE = T / Fits standard
BITPIX = 16 / Bits per pixel
NAXIS = 0 / Number of axes
EXTEND = T / File may contain extensions
ORIGIN = 'NOAO-IRAF FITS Image Kernel July 2003' / FITS file originator
IRAF-TLM= '2011-09-09T13:24:40'
NEXTEND = 4 / Number of standard extensions
DATE = '2010-04-02T19:53:08'
FILENAME= 'v971826aj_npl.fits' / name of file
FILETYPE= 'DXY GRID' / type of data found in data file
OBSTYPE = 'IMAGING ' / type of observation
TELESCOP= 'HST' / telescope used to acquire data
INSTRUME= 'ACS ' / identifier for instrument used to acquire data
DETECTOR= 'WFC' / detector in use: WFC, HRC, or SBC
FILTER1 = 'F475W ' / element selected from filter wheel 1
FILTER2 = 'CLEAR2L ' / element selected from filter wheel 2
USEAFTER= 'Mar 01 2002 00:00:00'
COMMENT = 'NPOL calibration file created by Ray A. Lucas 29 APR 2010'
DESCRIP = 'Residual geometric distortion file for use with astrodrizzle-------'
PEDIGREE= 'INFLIGHT 11/11/2002 11/11/2002'
HISTORY Non-polynomial offset file generated from qbu16420j_dxy.fits
HISTORY Only added to the flt.fits file and used in coordinate
HISTORY transformations if the npol reference filename is specified in
HISTORY the header. The offsets are copied from the reference file into
HISTORY two arrays for each chip. Each array is stored as a 65x33 pixel
HISTORY image that gets interpolated up to the full chip size. Two new
HISTORY extensions for each chip are also appended to the flt file
HISTORY (WCSDVARR).
HISTORY qbu16420j_npl.fits renamed to v9615069j_npl.fits on Sep 6 2011
HISTORY v9615069j_npl.fits renamed to v971826aj_npl.fits on Sep 7 2011
Data Extension Header
---------------------
Each ACS/WFC chip has a shape of 4096 x 2048 pixels,
yet the data arrays in this specific reference file only have 65x33 values.
Each data extension ('DX' and 'DY') contains only those keywords necessary to
properly interpolate the sub-sampled values from the arrays to apply to each individual
pixel in the full ACS/WFC exposure. The full header for the ['DX',1] extension contains::
XTENSION= 'IMAGE ' / Image extension
BITPIX = -32 / Bits per pixel
NAXIS = 2 / Number of axes
NAXIS1 = 65 / Axis length
NAXIS2 = 33 / Axis length
PCOUNT = 0 / No 'random' parameters
GCOUNT = 1 / Only one group
EXTNAME = 'DX ' / Extension name
EXTVER = 1 / Extension version
ORIGIN = 'NOAO-IRAF FITS Image Kernel July 2003' / FITS file originator
INHERIT = F / Inherits global header
DATE = '2004-04-28T16:44:21'
IRAF-TLM= '16:42:00 (30/11/2006)'
WCSDIM = 2
LTM1_1 = 1.
LTM2_2 = 1.
WAT0_001= 'system=physical'
WAT1_001= 'wtype=linear'
WAT2_001= 'wtype=linear'
CCDCHIP = 2 / CCDCHIP from full size dgeo file
LTV1 = 0
LTV2 = 0
ONAXIS1 = 4096 / NAXIS1 of full size dgeo file
ONAXIS2 = 2048 / NAXIS2 of full size dgeo file
CDELT1 = 64 / Coordinate increment along axis
CDELT2 = 64 / Coordinate increment along axis
.. _Appendix3:
*************************************
Appendix 3 - D2IMFILE Example
*************************************
The D2IMFILE reference file only contains a single 1-D array that should correct the
column (row) values based on the value of the 'AXISCORR' keyword in the SCI header.
FITS File Extensions
---------------------
This simple reference file, therefore, contains only 2 extensions; namely,
::
Filename: /grp/hst/cdbs/jref/v971826mj_d2i.fits
No. Name Type Cards Dimensions Format
0 PRIMARY PrimaryHDU 35 () int16
1 DX ImageHDU 18 (4096,) float32
PRIMARY Header
--------------
The PRIMARY header only needs to contain information on what detector this file corrects,
along with any available information on how this file was generated. The ACS/WFC D2IMFILE
PRIMARY header only includes::
SIMPLE = T / Fits standard
BITPIX = 16 / Bits per pixel
NAXIS = 0 / Number of axes
EXTEND = T / File may contain extensions
ORIGIN = 'NOAO-IRAF FITS Image Kernel July 2003' / FITS file originator
DATE = '2010-02-01T20:19:11' / Date FITS file was generated
IRAF-TLM= '2011-09-02T13:04:07' / Time of last modification
NEXTEND = 1 / number of extensions in file
FILENAME= 'v971826mj_d2i.fits' / name of file
FILETYPE= 'WFC D2I FILE' / type of data found in data file
OBSTYPE = 'IMAGING ' / type of observation
TELESCOP= 'HST' / telescope used to acquire data
INSTRUME= 'ACS ' / identifier for instrument used to acquire data
DETECTOR= 'WFC '
USEAFTER= 'Mar 01 2002 00:00:00'
COMMENT = 'D2I calibration file created by Warren Hack 29 APR 2010'
DESCRIP = 'Column-width correction file for WFC images------------------------'
PEDIGREE= 'INFLIGHT 11/11/2002 11/11/2002'
HISTORY
HISTORY Fixed column (or row) width correction file. This is applied
HISTORY as a correction to the input pixel position and the output of
HISTORY this correction is to be used as input to the polynomial and
HISTORY non-polynomial distortion corrections.
HISTORY
HISTORY For ACS WFC data, the correction is stored as an image extension
HISTORY (D2IMARR) with one row. Each element in the row specifies the
HISTORY correction in pixels for every pixel in the column (or row) in
HISTORY the science extension; for ACS WFC, the correction is in the X
HISTORY direction.
HISTORY
HISTORY For a more in-depth explanation of this file, please see the
HISTORY draft writeup at:
HISTORY http://stsdas.stsci.edu/stsci_python_epydoc/stwcs/fits_conventions.html
HISTORY wfc_ref68col_d2i.fits renamed to v961506lj_d2i.fits on Sep 6 2011
HISTORY v961506lj_d2i.fits renamed to v971826mj_d2i.fits on Sep 7 2011
In this case, most of the keywords not required by FITS describe how this file
was computed while also describing how it should be applied.
Data Extension Header
---------------------
The header keywords for the actual DX array simply needs to provide the information
necessary to apply the values to the data; namely,
::
XTENSION= 'IMAGE ' / Image extension
BITPIX = -32 / Bits per pixel
NAXIS = 1 / Number of axes
NAXIS1 = 4096 / Axis length
PCOUNT = 0 / No 'random' parameters
GCOUNT = 1 / Only one group
EXTNAME = 'DX ' / Extension name
EXTVER = 11 / Extension version
ORIGIN = 'NOAO-IRAF FITS Image Kernel July 2003' / FITS file originator
INHERIT = F / Inherits global header
DATE = '2009-03-18T19:28:09' / Date FITS file was generated
IRAF-TLM= '16:05:02 (18/03/2009)' / Time of last modification
CRPIX1 = 0 / Distortion array reference pixel
CDELT1 = 0 / Grid step size in first coordinate
CRVAL1 = 0 / Image array pixel coordinate
CRPIX2 = 0 / Distortion array reference pixel
CDELT2 = 0 / Grid step size in second coordinate
CRVAL2 = 0 / Image array pixel coordinate
The fact that these values get applied without interpolation to each pixel in a row,
in this case, means that no translation terms are needed in the header, making for